Ridge cap shingles covered in nails and caulk is failing. Why is this ridge cap covered in nails, well that’s a good question the answer is there is no good reason for these nails to be here. These need to be replaced before it begins leaking.
Go To Pin
2
Skylights not step flashed.
Skylights are not properly step flashed causing water penetration and roof decking to become rotted. That’s why you see the roof bowing in a downward angle between Skylights.
Go To Pin
3
improper pipe boot installation
Pipe boots are not installed correctly. The top of the pipe boot should be under the shingles leaving the bottom exposed acting like a shingle. This way the water sheds off correctly.
Go To Pin
4
Time for new flashing