  1. 1
    Video Of Inspection
    Go To Pin
  2. 2
    Chimney Caps Are Rusty

    All of the chimney caps on this building are rusty. They may not be currently leaking but eventually they might. If any water is observed getting in at the chimney, we recommend replacement of the cap.

    This is a picture of three chimney caps that are old and rusty This is a picture of an old rusty chimney cap on a steep roof

    Go To Pin
  3. 3
    Shingles In Good Shape

    The roof on this building appears to be in good shape. All shingles are correctly staggered with the appropriate distance between shingles. All shingles have step flashing at the walls to prevent any leaks. Pipe boots are in good shape and all nails sealed correctly.

    This is a picture of shingles that are correctly staggered This is a picture of shingles at a wall with step flashing underneath This is a picture of a pipe boot in good shape

    Go To Pin
  4. 4
    Ridges In Good Shape

    All the ridge vents on this building are in good shape. No missing shingles were observed. The ridges at all of the dormers were also in good shape with ridge shingles.

    This is a picture of a ridge vent with ridge cap shingles This is a picture of a dormer with ridge cap shingles in good shape

    Go To Pin