Top of roof looking east

‹ EPDM Commercial roof in Knoxville
  1. 1
    Failing sealant

    There are a total of about 18 of these areas with failing sealant.

    This is an image of sealant that is failing.

    ย 

    Go To Pin
  2. 2
    old patch coming apart

    This EPDM patch is coming apart and complete failure is imminent.

    This is an patch on an black EPDM roof that is no longer sealed.

    ย 

    Go To Pin
  3. 3
    failing cover strip

    This tape joint is loose enough we can stick our hand under it.ย  We should not be able to do this.ย  ย If it isnโ€™t letting water in now, then it wonโ€™t be long before it is.ย 

    This is a picture of black cover strip that is failing.

    ย 

    Go To Pin
  4. 4
    A soft, low spot in roof.

    This section of the roof is very soft and feels like a trampoline when stepping on it. The roof protrudes downward about 5โ€ณ when stepping on it.

    This is the picture of the flat roof with a soft spot.

    Go To Pin
  5. 5
    A.C. Unit low on the roof.

    A.C. unit should be off the roof as the rest of the roof units.ย 

    This is a picture of an AC unit that is too low on the roof.

    Go To Pin