This commercial roof is only three or four years old. The inspection reveals quite a few problems with this commercial roof.

1. Recurring Leaks

2. Ponding Water in drains

3. Bad Roof Edges

These problems can turn into significant issues if not addressed.

Painting and Coating this Roof

  1. 1
    Possibly Painting this Elevator Building

    We have been asked to paint this elevator building on top of this roof possibly. We would recommend elastomeric paint because of the Masonry.

    Go To Pin
  2. 2
    Possibly coating this roof

    This Roof has had several leaks Since it was installed. The owners of this building want to consider a permanent solution. This might be a good route to consider putting an Aldo silicone coding system on.

    Go To Pin
  3. 3
    Roof Inspection Video
    Go To Pin

Commercial Roof Drainage Problems

  1. 1
    3 Roof Drains All have Standing Water

    All three of the roof drains in the back of the roof have standing water.

    Standing water on commercial roof at a drain Standing water on commercial roofs can cause leaks Scupper drain with standing water on a commercial roof

    Go To Pin
  2. 2
    Cutting the scupper drains to flow better

    It is very disappointing to have ponding water on the back of this roof.  Because the roof has such a beautiful slope and fall from the front to the back. It’s very unfortunate that the back of the roof ponds water at the drains.

    With that said the recommendation on how to resolve this standing water is to open the drain up at the bottom this will require cutting through the wall with the lower channel so that the water can pass easier instead of ponding on this commercial roof.

    Go To Pin
  3. 3
    Cutting the drains lower

    In order to cut these drains lower we will need to break the brick on the outside of the wall so that we can make a drain that is lower here’s a picture of the outside wall as the drain goes into a gutter box.

    Commercial roof drain into a gutter box

    Go To Pin

Commercial Drip Edge Should Have Been Used Here

  1. 1
    Termination Bar Mis-Installed

    This T-bar should’ve never been installed on the flat of a roof because water can go in at the screws holding the T-bar on and caused the roof to rot and leak. A commercial drip edge needs to be installed here instead.

    This is what commercial drip edge would look like on the edge of this roof.

    Commercal Roof Drip Edge

    Go To Pin
  2. 2
    Bad Installation on Edge of Roof

    Termination Bar On Commercial Roof is Misinstalled

    Go To Pin