EPDM Commercial roof in Knoxville, TN

Commercial roofs with a lot of equipment or penetrations will have a greater chance of leaking.

This commercial roof has approximately 50 HVAC units floating above the roof.Β  A rail system suspends them, so they do not require roof penetrations.Β  The rail system makes it easier to prevent roof leaks and roof problems.

Unfortunately, this roof still has a leak issue that Litespeed Construction is resolving.

top of roof

  1. 1
    Areas that could be causing the leaks.

    We discovered cracks, holes, and weak points in the EPDM at corners and penetration areas that could be causing leaks.Β 

    Β 

    This is black EPDM with a puncture hole, possible causing the roof leak. This is an areal of the EPDM that is damaged, another possible leak area. This is black EPDM at a corner that has a small tear.

    Β 

    Go To Pin
  2. 2
    EPDM Flashing Tape is loose.

    EPDM flashing tape is coming loose that could be another area that is leaking.

    This is a picture of black EPDM with a pen inserted in the lap, possible cause of the leak.

    Up close image of a lap in the EPDM showing it is unsealed.

    Go To Pin
  3. 3
    Wall needs resealed

    The old sealant is rotted and coming loose and needs to be sealed with a suitable elastomer.

    Β 

    This is a the EPDM at the wall that is no longer sealed. A pen can be inserted between the wall and EPDM.

    A close up image of the EPDM at the wall that is not sealed and tearing away from wall.

    Β 

    Go To Pin

Top of roof looking east

  1. 1
    Failing sealant

    There are a total of about 18 of these areas with failing sealant.

    This is an image of sealant that is failing.

    Β 

    Go To Pin
  2. 2
    old patch coming apart

    This EPDM patch is coming apart and complete failure is imminent.

    This is an patch on an black EPDM roof that is no longer sealed.

    Β 

    Go To Pin
  3. 3
    failing cover strip

    This tape joint is loose enough we can stick our hand under it.Β  We should not be able to do this.Β  Β If it isn’t letting water in now, then it won’t be long before it is.Β 

    This is a picture of black cover strip that is failing.

    Β 

    Go To Pin
  4. 4
    A soft, low spot in roof.

    This section of the roof is very soft and feels like a trampoline when stepping on it. The roof protrudes downward about 5β€³ when stepping on it.

    This is the picture of the flat roof with a soft spot.

    Go To Pin
  5. 5
    A.C. Unit low on the roof.

    A.C. unit should be off the roof as the rest of the roof units.Β 

    This is a picture of an AC unit that is too low on the roof.

    Go To Pin